EMS 01 OD 422 - May 2006
STANDARDS COVERED
BY THE KEYMARK EMS 01
|
Ref. |
Standards |
Year of issue |
Title |
Limitations
|
|
K1 |
EN 60335-1 |
2002 |
Household
and similar electrical appliances. |
1, 2, 3,
4, 16 |
|
K2.2 |
EN 60335-2-2 |
2003 |
Vacuum
cleaners and water suction |
none |
|
K2.3 |
EN 60335-2-3 |
2002 |
Electric
irons |
none |
|
K2.4 |
EN 60335-2-4 |
2002 |
Spin
extractors |
none |
|
K2.5 |
EN 60335-2-5 |
2003 |
Dishwashers |
none |
|
K2.6 |
EN 60335-2-6 |
2003 |
Stationary cooking ranges, hobs, ovens |
13 |
|
K2.7 |
EN 60335-2-7 |
2003 |
Washing
machines |
5 |
|
K2.8 |
EN 60335-2-8 |
2003 |
Shavers,
hair clippers |
none |
|
K2.9 |
EN 60335-2-9 |
2003 |
Toasters,
grills, roasters |
none |
|
K2.10 |
EN 60335-2-10 |
2003 |
Floor
treatment & wet scrubbing machines |
none |
|
K2.11 |
EN 60335-2-11 |
2003 |
Tumble
dryers |
none |
|
K2.12 |
EN 60335-2-12 |
2003 |
Warming
plates |
none |
|
K2.13 |
EN 60335-2-13 |
2003 |
Deep fat
fryers, frying pans |
none |
|
K2.14 |
EN 60335-2-14 |
2002 |
Kitchen
machines |
none |
|
K2.15 |
EN 60335-2-15 |
2002 |
Appliances
for heating liquids |
none |
|
K2.16 |
EN 60335-2-16 |
2003 |
Food
waste disposers |
6 |
|
K2.17 |
EN 60335-2-17 |
2002 |
Blankets,
pads |
none |
|
K2.21 |
EN 60335-2-21 |
2003 |
Water
heaters |
15 |
|
K2.23 |
EN 60335-2-23 |
2003 |
Appliances
for skin and hair care |
none |
|
K2.24 |
EN 60335-2-24 |
2003 |
Refrigerators,
food freezers and icemakers |
none |
|
K2.25 |
EN 60335-2-25 |
2002 |
Microwave
ovens |
none |
|
K2.26 |
EN 60335-2-26 |
2003 |
Clocks |
none |
|
K2.27 |
EN 60335-2-27 |
2003 |
UV and
IR skin treatment appliances |
none |
|
K2.28 |
EN 60335-2-28 |
2003 |
Sewing
machines |
none |
|
K2.29 |
EN 60335-2-29 |
2004 |
Battery
chargers |
7 |
|
K2.30 |
EN 60335-2-30 |
2002 |
Room heaters
|
8, 9 |
|
K2.31 |
EN 60335-2-31 |
2003 |
Range
hoods |
10 |
|
K2.32 |
EN 60335-2-32 |
2003 |
Massage
appliances |
none |
|
K2.34 |
EN 60335-2-34 |
2002 |
Motor
compressors |
none |
|
K2.35 |
EN 60335-2-35 |
2002 |
Instantaneous
water heaters |
none |
|
K2.36 |
EN
60335-2-36 |
2002 |
Commercial
electric cooking ranges |
|
|
K2.37 |
EN
60335-2-37 |
2002 |
Commercial
electric deep fat fryers |
|
|
K2.38 |
EN
60335-2-38 |
2003 |
Commercial
electric griddles |
|
|
K2.39 |
EN
60335-2-39 |
2003 |
Commercial
electric multi-purpose cooking pans |
|
|
K2.40 |
EN 60335-2-40 |
2003 |
Heat
pumps, air conditioners & dehumidifiers |
None |
|
K2.41 |
EN 60335-2-41 |
2003 |
Pumps
for liquids |
none |
|
K2.42 |
EN 60335-2-42 |
2003 |
Commercial
electric forced convection ovens |
|
|
K2.43 |
EN 60335-2-43 |
2003 |
Clothes
dryers and towel rails |
none |
|
K2.44 |
EN 60335-2-44 |
2002 |
Ironers |
none |
|
K2.45 |
EN 60335-2-45 |
2002 |
Portable
heating tools |
none |
|
K2.47 |
EN 60335-2-47 |
2003 |
Commercial
electric boiling pans |
|
|
K2.48 |
EN 60335-2-48 |
2003 |
Commercial
grillers and toasters |
|
|
K2.49 |
EN 60335-2-49 |
2003 |
Commercial
electric hot cupboards |
|
|
K2.50 |
EN 60335-2-50 |
2003 |
Commercial
electric bain-marie |
|
|
K2.51 |
EN 60335-2-51 |
2003 |
Stationary
circulation pumps for heating and service water installations |
none |
|
K2.52 |
EN 60335-2-52 |
2003 |
Oral
hygiene appliances |
none |
|
K2.53 |
EN 60335-2-53 |
2002 |
Sauna
heating appliances |
none |
|
K2.54 |
EN 60335-2-54 |
2003 |
Surface-cleaning
appliances employing liquids |
11 |
|
K2.55 |
EN 60335-2-55 |
2003 |
Appliances
for aquariums/garden ponds |
none |
|
K2.56 |
EN 60335-2-56 |
2003 |
Projectors
|
none |
|
K2.58 |
EN 60335-2-58 |
2005 |
Commercial
electric dishwashing machines |
|
|
K2.59 |
EN 60335-2-59 |
2003 |
Insect
killers |
|
|
K2.60 |
EN 60335-2-60 |
2003 |
Whirlpool
baths |
none |
|
K2.61 |
EN 60335-2-61 |
2003 |
Thermal
storage room heaters |
12 |
|
K2.62 |
EN 60335-2-62 |
2003 |
Commercial
electric water boilers |
|
|
K2.64 |
EN 60335-2-64 |
2000 |
Commercial
electric kitchen machines |
|
|
K2.65 |
EN 60335-2-65 |
2003 |
Air-cleaning
appliances |
none |
|
K2.66 |
EN 60335-2-66 |
2003 |
Water-bed
heaters |
none |
|
K2.67 |
EN 60335-2-67 |
2003 |
Floor
treatment and floor cleaning machines, for industrial and commercial use |
|
|
K2.68 |
EN 60335-2-68 |
2003 |
Spray
extraction appliances, for industrial and commercial use |
|
|
K2.69 |
EN 60335-2-69 |
2003 |
Wet and
dry vacuum cleaners, for industrial and commercial use |
|
|
K2.70 |
EN 60335-2-70 |
2002 |
Milking
machines |
none |
|
K2.71 |
EN 60335-2-71 |
2003 |
Heating
appliances for breeding/rearing animals |
none |
|
K2.72 |
EN 60335-2-72 |
1998 |
Automatic
machines for floor treatment, for industrial and commercial use |
|
|
K2.73 |
EN 60335-2-73 |
2003 |
Fixed
immersion heaters |
none |
|
K2.74 |
EN 60335-2-74 |
2003 |
Portable
immersion heaters |
none |
|
K2.75 |
EN 60335-2-75 |
2004 |
Commercial
dispensing appliances and vending machines |
|
|
K2.76 |
EN 60335-2-76 |
2005 |
Electric
fence energizers |
|
|
K2.77 |
EN 60335-2-77 |
2000 |
Pedestrian
controlled mains-operated lawnmowers |
|
|
K2.78 |
EN 60335-2-78 |
2003 |
Outdoor
barbecues |
None |
|
K2.79 |
EN 60335-2-79 |
2004 |
High
pressure cleaners and steam cleaners, for industrial and commercial use |
|
|
K2.80 |
EN 60335-2-80 |
2003 |
Fans |
none |
|
K2.81 |
EN 60335-2-81 |
2003 |
Foot
warmers and heating mats |
none |
|
K2.82 |
EN 60335-2-82 |
2003 |
Service
and amusement machines |
none |
|
K2.83 |
EN 60335-2-83 |
2002 |
Heated
gullies for roof drainage |
|
|
K2.84 |
EN 60335-2-84 |
2003 |
Toilets |
none |
|
K2.85 |
EN 60335-2-85 |
2003 |
Garment
and fabric steamers |
|
|
K2.86 |
EN 60335-2-86 |
2003 |
Electric
fishing machines |
14 |
|
K2.87 |
EN 60335-2-87 |
2002 |
Animal
stunning equipment |
none |
|
K2.88 |
EN 60335-2-88 |
2002 |
Humidifiers
for use with heating, ventilation or air conditioning systems |
none |
|
K2.89 |
EN 60335-2-89 |
2002 |
Commercial
refrigerating appliances |
|
|
K2.90 |
EN 60335-2-90 |
2006 |
Commercial
microwave ovens |
|
|
K2.91 |
EN 60335-2-91 |
2003 |
Walk-behind
and handheld lawn-trimmers |
|
|
K2.92 |
EN 60335-2-92 |
2005 |
Pedestrian
controlled mains-operated lawn scarifiers and aerators |
|
|
K2.95 |
EN 60335-2-95 |
2004 |
Drives
for vertically moving garage doors for residential use |
|
|
K2.96 |
EN 60335-2-96 |
2002 |
Flexible
sheet heating elements for room heating |
|
|
K2.97 |
EN 60335-2-97 |
2000 |
Drives
for rolling shutters, awnings, blinds |
none |
|
K2.98 |
EN 60335-2-98 |
2003 |
Humidifiers
|
none |
|
K2.99 |
EN 60335-2-99 |
2003 |
Commercial
electric hoods |
|
|
K2.101 |
EN 60335-2-101 |
2002 |
Vaporizers |
|
|
K2.103 |
EN 60335-2-103 |
2003 |
Drives
for gates, doors and windows |
|
Limitations
1. Plugs
The Agreement covers the appliances
listed including their supply cord (if any) but excluding their plug.
Appliances with a supply cord or cord
set marketed in a member country, shall be provided with a plug which is
appropriate for that country and which has been certified according to the
relevant standard.
2. Special National Condition for
Appliances permanently connected to
fixed wiring having a single pole switch cannot be used. In order to avoid this
use it should be indicated in the instructions for use as well as in the
licence document: “Not suitable for use in
3. Special National Condition for
Appliances having circuits which may
cause under one fault condition (e.g. failure of basic insulation*) an earth
leakage current having a d.c. component exceeding 5mA or exceeding 20% of the
total earth leakage current, whatever is the higher, shall be accompanied with
instructions giving the necessary information with regard to the required type
of residual current device.
(*) Failure of double or reinforced
insulation is not taken into account.
4. Special National Condition for
Appliances having a rated current over
10A up to and including 13A supplied with a power supply cord having a nominal
cross-sectional area of less than 1.5 mm2 are excluded from the
scheme.
5. Special National Condition for
Washing machines not complying with
this test carried out at twice the permissible inlet pressure or 2.0 Mpa,
whichever is the greater, are not allowed. In order to make this known it
should be indicated in the instructions for use as well as in the licence
document of such machines. “Not suitable for use in
6. Special National Condition or A-deviation
for
Installation of food waste disposers
is not allowed or depends upon permission of authorities responsible for the
sewage systems. In order to make this known this information should be
indicated in the instructions for use as well as in the licence document (in
instructions for use in the language(s) of all relevant countries).
7. Special
National Condition for
Polyvinylchloride
sheathed cords are not allowed for chargers for charging automobile batteries
in outdoor use or locations where the temperature is equal to the outdoor
temperature.
In order to avoid this it should be
indicated in the instructions for use as well as in the licence document: “Not
suitable for use in
NOTE
An action was started in April 2000 by
the Finnish Authorities for the withdrawal of this Special National Condition
for
8. A-deviation for
Fixed room heaters other than those
for mounting at high level, for which the temperature rise of air-outlet
grilles and their immediate surround exceeds 115K, are not allowed to be used.
In order to make this known it should be indicated in the instructions for use
as well as in the licence document of such heaters: “Not suitable for use in
9. Special National Condition for
Fixed room heaters which are not
intended to be permanently connected to fixed wiring cannot be used.
In order to avoid this it should be
indicated in the instructions for use as well as in the licence document of
such heaters: “Not suitable for use in
10. A-deviations for
Range hoods of the exhaust-air type
without the following warnings near the exhaust-air opening (7.1) and in the
instructions for use (7.12) are not allowed :
(7.1) Achtung ! Warnhinweis zum
Abluftbetrieb im Anweisungsblatt beachten.
(7.12) Bei gleichzeitigem Betrieb der
Dunstabzugshaube im Abluftbetrieb und Feuerstätten darf im Austellraum der
Feuerstätte der Unterdruck nicht grösser als 4 Pa (4 x 10-5 bar) sein (or
similar text).
In
order to make this known it should be indicated in the instructions for use as
well as in the licence document of such range hoods: “Not suitable for use in
11. Special National Condition for The
Netherlands (EN 60335-2-54, surface cleaning appliances, Subcl. 6.1):
Handheld cleaning appliances other
than those of Class II and Class III are not allowed. In order to make this
known it should be indicated in the instructions for use as well as in the
licence document of such appliances: “Not suitable for use in The Netherlands”
(in instructions for use in Dutch language only).
12. A-deviation for
Thermal storage room heaters of which
the temperature rise for air-outlet grilles and their immediate surrounds
exceeds 130K are not allowed. In order to make this known it shall be indicated
in the instructions for use as well as the licence document of such heaters:
“Not suitable for use in
13. A-deviation
for
Cooking
ranges shall be constructed, or be provided with devices, so that the hob
elements, with cooking utensils placed on them, are not or cannot be made
easily accessible to children. Ovens shall be constructed so that they are not
or cannot be made easily accessible to children.
For
cooking ranges or ovens which do not comply with the above-mentioned
requirement, it should be indicated in the instructions for use, as well as in
the licence document: “Not suitable for use in
NOTE (see EN 60335-2-6: 1999 – Annex
ZB)
Cooking
ranges having hob elements located at a distance from the front of the hob so
that they are out of easy reach of children and cooking ranges, the hob of
which is or can be provided with a protective guard reaching at least
Ovens
intended to be placed at a height exceeding
14. A-deviation
for
The use of alternating current for
catching fish is not allowed. For fishing machines which do not comply with the
above-mentioned requirement, it should be indicated in the instructions for
use, as well as in the licence document: “Not suitable for use in
15. Special
National Condition for
For
closed water heaters, the minimum rated pressure is 1,0 MPa.
When these Special National Conditions
have not been covered the Instructions for Use and the Licence Document should
say: "Not suitable for use in
A-deviation for
In addition to a non-self-resetting
thermal cut-out, any closed water heater having a storage capacity in excess of
When this Deviation has not been
covered the Instructions for Use and the Licence Document should say: "Not
suitable for use in
A-deviation
for
The water temperature of the stored
water shall not at any time exceed 99ºC in closed water heaters having a
storage capacity in excess of
When this Deviation has not been
covered the Instructions for Use and the Licence Document should say: "Not
suitable for use in
A-deviation for
Components
shall have a minimum rated pressure of 1,0 MPa.
When
this Deviation has not been covered the Instructions for Use and the Licence
Document should say: "Not suitable for use in
16. Socket outlets on appliances
The
Agreement excludes socket-outlets on appliances for the supply of other
appliances if these socket-outlets are compatible with plugs for which
limitation 1 applies. Such socket-outlets shall be appropriate for the country
in which the appliance is marketed and have to be certified according to the
relevant standard.