LIST OF CABLE TYPES COVERED BY THE HAR AGREEMENT

 

according to HAR PD 7 - 0ctober 2009

 

red printing = new or amended items

 

Ref.

 

(GrCod)

Type

 

description

Code

 

Designation

Starting or beginning for updating licences

Deadline for updating licences

 

Standard or Harmonization

Document

 

Clause

 

1.   THERMOPLASTIC INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V

 

H1.1

 

Flat tinsel cords

 

H03VH-Y

 

running

 

HD 21.5 S3

+ /A1:1999

+ /A2:2001

 

2

 

H1.2

 

Spare

 

H1.3

 

Light PVC sheathed cords (round)

Light PVC sheathed cords (Flat)

 

 

H03VV-F

H03VVH2-F

running

 

HD 21.5 S3

+ /A1:1999

+ /A2:2001

4

 

 

H1.4

 

Ordinary  PVC sheathed cords (round)

Ordinary PVC sheathed cords (Flat)

 

 

H05VV-F

H05VVH2-F

running

5

 

H1.5

 

Single core non- sheathed cables with solid or flexible conductor for internal wiring

 

H05V-U

H05V-R

H05V-K

 

2008-09-01

2010-09-01

(dow)

 

HD 21.3 S3

+ /A1:1999

+ /A2:200

4 and 5

 

H1.6

 

Single core non- sheathed cables with solid or flexible conductor for general purposes

 

H07V-U

H07V-R

H07V-K

 

2008-09-01

2010-09-01

(dow)

2 and 3

 

H1.7

 

Single core non- sheathed cables for internal wiring for a conductor temperature of  90 °C

 

H05V2-U

H05V2-K

H05V2-R

 

running

 

HD 21.7 S2

/A1:1999

2

 

H1.8

 

Single core non- sheathed cables for internal wiring for a conductor temperature of  90 °C

 

H07V2-U

H07V2-K

H07V2-R

 

running

3

 

H1.9

 

Single core insulated cables for indoor decorative lighting  chains

 

 

H03VH7-H

running

 

HD 21.8 S2

3

 

H1.10

 

Single core non- sheathed cables with rigid or flexible conductor for installation at low temperature

 

 

H07V3-U

H07V3-R

H07V3-K

running

 

HD 21.9 S2

+ /A1:1999

 

2 and 3

 

H1.11

 

Light PVC insulated and sheathed extensible leads

 

 

H03VVH8-F

H03VVH2H8-F

running

 

HD 21.10 S2

2

 

H1.12

 

Ordinary  PVC insulated and sheathed extensible leads

 

 

H05VVH8-F

H05VVH2H8-F

running

3

 

H1.13

 

Divisible, two-layer insulated cables for Class II luminaires

 

 

H03VH7H-F

running

 

HD 21.11 S1

+ /A1:2001

3

 

H1.14

 

Heat-resistant light PVC sheathed cords for a maximum conductor temperature of 90°C

 

H03V2V2-F

H03V2V2H2-F

 

running

 

HD 21.12 S1

+ /A1:2001

2

 

H1.15

 

Heat-resistant Ordinary PVC sheathed cords for a maximum conductor temperature of 90°C

 

 

H05V2V2-F

H05V2V2H2-F

running

3

 

H1.16

 

Heat-resistant Ordinary PVC sheathed cords with strain  bearing members for a maximum conductor temperature of 90°C

 

 

 

H05V2V2D3-F

 

running

4

 

H1.17

 

Oil resistant PVC sheathed, unscreened cables with two or more conductors

 

 

H05VV5-F

 

running

 

HD 21.13 S1

+ /A1:2001

3

 

H1.18

 

Oil resistant PVC sheathed, screened cables with two or more conductors

 

 

H05VVC4V5-K

 

running

4

 

H1.19

 

Light flexible cords insulated and sheathed with halogen free thermoplastics compounds

 

H03Z1Z1-F

H03Z1Z1H2-F

 

running

 

HD 21.14 S1

3

 

H1.20

 

Ordinary flexible cords insulated and sheathed with halogen free thermoplastics compounds

 

H05Z1Z1-F

H05Z1Z1H2-F

 

running

4

 

H1.21

 

Single core non-sheathed cable insulated with halogen-free thermoplastic compound with rigid or flexible conductor for general purposes

 (Type 1)

 

 

H07Z1-U

H07Z1-R

H07Z1-K

 

running

 

HD 21.15 S1

4 and 5

 

H1.22

 

Single core non-sheathed cable insulated with halogen-free thermoplastic compound with rigid or flexible conductor for general purposes

 (Type 2)

 

 

H07Z1-U

H07Z1-R

H07Z1-K

 

running

4 and 5

 

H1.23

 

Single core non-sheathed cable insulated with halogen-free thermoplastic compound with rigid or flexible conductor for internal wiring

 

 

H05Z1-U

H05Z1-R

H05Z1-K

 

running

6 and 7

2.   CROSS-LINKED INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V

 

H2.1

 

Heat resistant silicon rubber insulated cables for a maximum conductor temperature of 180 °C

H05SJ-K

H05SJ-U

running

HD 22.3 S4 + /A1:2006

 

2

 

H2.2

 

Unbraided heat resistant silicon rubber insulated cables for a maximum conductor temperature of 180 °C

 

 

H05S-U

H05S-K

running

3

 

H2.3

 

Heat resistant silicone rubber sheathed single core  cables

 

H05SS-K

running

4

 

H2.4

 

Spare

 

 

H2.5

 

Ordinary tough rubber sheathed cords and flexible cables

 

 

H05RR-F

running

HD 22.4 S4

3

 

H2.6

 

Ordinary  PCP or other equivalent synthetic elastomer sheathed cords and flexible cables

 

 

H05RN-F

running

4

 

H2.7

 

Heavy  PCP or other equivalent synthetic elastomer sheathed flexible cables

 

 

H07RN-F

running

5

 

H2.8

 

Heavy  PCP or other equivalent synthetic elastomer sheathed flexible cables with more than five conductors

 

 

H07RN-F

running

6

 

H2.9

 

Arc welding cables

 

 

H01N2-D

H01N2-E

 

running

 

HD 22.6 S2

+ /A1:1999

+/A2:2004

2

 

H2.10

 

Cables with increased heat resistance for internal wiring for a conductor temperature of 110 °C

 

 

H07G-U

H07G-R

H07G-K

 

running

 

HD 22.7 S2

+ /A1:1999

+ /A2:2004

2

 

H2.11

 

Cables with increased heat resistance for internal wiring for a conductor temperature of 110 °C

 

 

H05G-U

H05G-K

running

3

 

H2.12

 

PCP or equivalent synthetic elastomer sheathed cables for use as decorative chains

 

 

H05RN-F

H05RNH2-F

running

HD 22.8 S2

+ /A1:1999

2

 

H2.13

 

PCP or equivalent synthetic elastomer sheathed cables for  decorative chains used with designated lampholders

 

 

H03RN-F

running

3

 

H2.14

 

Single core non sheathed cables with rigid conductors for general purposes

 

 

H07Z-U

H07Z-R

running

HD 22.9

2

 

H2.15

 

Single core non sheathed cables with flexible conductors for general purposes

 

 

H07Z-K

running

3

 

H2.16

 

Single core non sheathed cables with solid conductors for internal wiring

 

 

H05Z-U

running

4

 

H2.17

 

Single core non sheathed cables with flexible conductors for internal wiring

 

H05Z-K

running

5

 

H2.18

 

EPR insulated and polyurethane sheathed flexible cable

 

 

H05BQ-F

running

HD 22.10 S2

3

 

H2.19

 

EPR insulated and polyurethane sheathed flexible cable

 

 

H07BQ-F

running

4

 

H2.20

 

EVA cords and flexible cables

 

H05GG-F

H05GGH2-F

running

 

HD 22.11 S2

3

 

H2.21

 

Ordinary heat-resistant EPR or equivalent synthetic elastomer insulated and sheathed cord and cable for a maximum conductor temperature of 90 °C

 

 

H05BB-F

running

HD 22.12 S2

3

 

H2.22

 

Heavy heat-resistant EPR or equivalent synthetic elastomer insulated and sheathed cord and cable for a maximum conductor temperature of 90 °C

 

 

H07BB-F

running

4

 

H2.23

 

Ordinary heat-resistant EPR or equivalent synthetic elastomer insulated and CSP or equivalent synthetic elastomer sheathed cord and cable for a maximum conductor temperature of 90 °C

 

 

H05BN4-F

running

5

 

 

H2.24

 

Heat-resistant EPR or equivalent synthetic elastomer insulated heavy CSP or equivalent synthetic elastomer sheathed cord and cable for a maximum conductor temperature of 90°C

 

 

H07BN4-F

running

6

 

H2.25

 

Heat-resistant EPR or equivalent synthetic elastomer insulated heavy CSP or equivalent synthetic elastomer sheathed cord and cable for a maximum conductor temperature of 90 °C (multicore cables)

 

 

H07BN4-F

running

7

 

H2.26

 

Single and multicore flexible cables, insulated and sheathed with cross-linked polymer and having low emission of smoke and corrosive gases. Cables with one to five cores

 

 

 

H07ZZ-F

running

 

HD 22.13 S2

3

 

H2.27

 

Multicore flexible cables, insulated and sheathed with cross-linked polymer and having low emission of smoke and corrosive gases. Cables with more than five cores

 

 

H07ZZ-F

running

4

 

H2.28

 

EPR insulated and sheathed cords for applications requiring high flexibility

 

 

H03RR-H

running

HD 22.14 S3

3

H2.29

Spare

---

 

H2.30

 

Cross-linked PVC (XLPVC) insulated and sheathed cords for applications requiring high flexibility

 

 

H03V4V4-H

running

5

 

H2.31

 

EPR insulated and braided cords for applications requiring high flexibility

 

 

H03RT-H

running

6

 

H2.32

 

Heat resistance silicone rubber sheathed multicore flexible cables without strain-bearing element

 

 

H05SS-F

H05SST-F

running

HD 22.15 S2

3

 

H2.33

 

Heat resistance silicone rubber sheathed multicore cables with strain-bearing element

 

 

H05SSD3-K

H05SSD3T-K

running

HD 22.15 S2

4

 

H2.34

 

Water resistant polychloroprene or equivalent synthetic elastomer sheathed cables

 

 

H07RN8-F

 

running

HD 22.16 S2

3

 

H2.35

 

Water resistant polychloroprene or other equivalent synthetic elastomer sheathed  flexible cable with more than five conductors (multicore cables)

 

 

H07RN8-F

 

running

4

3.   FLAT PVC SHEATHED FLEXIBLE CABLES

H3.1

Spare

 

H3.2

 

Flat PVC sheathed flexible cables for low rise lifts

 

 

H05VVH6-F

H05VVD3H6-F

 

running

EN 50214:2006

5

 

H3.3

 

Flat PVC sheathed flexible cables for high rise, high speed lifts

 

 

H05V3V3H6-F

H05V3V3D3H6-F

 

running

6

 

H3.4

 

Flat PVC sheathed flexible cables for lifts and similar applications

 

 

H07VVH6-F

H07VVD3H6-F

 

running

7

4.   SPARE

5.   MINERAL INSULATED CABLES WITH A RATED VOLTAGE NOT EXCEEDING 750 V

H5.1

Spare

H5.2

Spare

 

H5.3

 

500 V mineral insulated cables

(light duty grade)

 

 

500 V

 

running 

EN 60702-1:2002

4.1

 

H5.4

 

750 V mineral insulated cables

(heavy duty grade)

 

 

750 V

 

running

4.2

6.   CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM
      A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1 kV BUT NOT EXCEEDING 10 kV

 

H6.1

Rubber insulated lead sheathed cables

Type A

running

2012-01-31

(cancellation)

 

EN 50143:2009

 

6

H6.2

 

Silicone rubber insulated cables:

7

 

Unscreened, unsheathed

 

 

Type B

 

2009-02-01

2012-01-31

 

 

 

Unscreened, PVC sheathed

 

 

Type C1

 

running

2012-01-31

(cancellation)

 

 

Unscreened, halogen free sheathed

 

 

Type C2

 

2009-02-01

2012-01-31

 

 

Screened and PVC sheathed

 

 

Type D1

running

2012-01-31

(cancellation)

Screened and halogen free sheathed

Type D2

2009-02-01

2012-01-31

H6.3

PVC insulated cables

EN 50143:2009

8

 

Screened and PVC sheathed

 

Type E

 

2009-02-01

2012-01-31

 

 

Unscreened PVC sheathed

 

Type F

 

2009-02-01

2012-01-31

 

Unscreened, unsheathed

 

Type G

2009-02-01

2012-01-31

 

H6.4

Cable with a composite insulation of polyethylene and PVC

Type H

running

2012-01-31

(cancellation)

9

Cable with a reduced thickness composite insulation of polyethylene and PVC

Type K

2009-02-01

2012-01-31

 

 

H6.5

Silicone Rubber insulated cables (3/6 kV)

Type L

2009-02-01

2012-01-31

10

7.   CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT

 

H7.1

 

Earthing and short-circuiting cables:

 

- EPR/Copper

- EPR/Aluminium

- PVC/Copper (T from -5 ºC to 70 ºC)

- PVC/Aluminium (T from -5 ºC to 70 ºC)

- PVC/Copper (T from -25 ºC to 55 ºC)

- PVC/Aluminium (T from -25 ºC to 55 ºC)

 

 

 

 

61138 IEC 110

61138 IEC 210

H00V-D

H00V-AD

H00V3-D

H00V3-AD

 

2007-10-01

2009-10-01

(dow)

EN 61138:2007

---

H7.2

 

-       SiR – Copper

-       SiR – Aluminium

 

H00S-D

H00S-AD

 

2007-10-01

2009-10-01
 (dow)

EN 61138:2007

---