LIST OF CABLE TYPES COVERED BY THE HAR AGREEMENT
according to HAR
PD 7 - 0ctober 2009
red printing = new or amended items
|
Ref. (GrCod) |
Type description |
Code Designation |
Starting or beginning for updating licences |
Deadline for updating licences |
Standard or
Harmonization Document |
Clause |
|
1. THERMOPLASTIC
INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V |
||||||
|
H1.1 |
Flat tinsel cords |
H03VH-Y |
running |
HD 21.5 S3 + /A1:1999 + /A2:2001 |
2 |
|
|
H1.2 |
Spare |
|||||
|
H1.3 |
Light PVC sheathed cords (round) Light PVC sheathed cords (Flat) |
H03VV-F H03VVH2-F |
running |
HD 21.5 S3 + /A1:1999 + /A2:2001 |
4 |
|
|
H1.4 |
Ordinary PVC
sheathed cords (round) Ordinary PVC sheathed cords (Flat) |
H05VV-F H05VVH2-F |
running |
5 |
||
|
H1.5 |
Single core non- sheathed cables with solid or
flexible conductor for internal wiring |
H05V-U H05V-R H05V-K |
2008-09-01 |
2010-09-01 (dow) |
HD 21.3 S3 + /A1:1999 + /A2:200 |
4 and 5 |
|
H1.6 |
Single core non- sheathed cables with solid or
flexible conductor for general purposes |
H07V-U H07V-R H07V-K |
2008-09-01 |
2010-09-01 (dow) |
2 and 3 |
|
|
H1.7 |
Single core non- sheathed cables for internal wiring
for a conductor temperature of |
H05V2-U H05V2-K H05V2-R |
running |
HD 21.7 S2 /A1:1999 |
2 |
|
|
H1.8 |
Single core non- sheathed cables for internal wiring
for a conductor temperature of |
H07V2-U H07V2-K H07V2-R |
running |
3 |
||
|
H1.9 |
Single core insulated cables for indoor decorative
lighting chains |
H03VH7-H |
running |
HD 21.8 S2 |
3 |
|
|
H1.10 |
Single core non- sheathed cables with rigid or
flexible conductor for installation at low temperature |
H07V3-U H07V3-R H07V3-K |
running |
HD 21.9 S2 + /A1:1999 |
2 and 3 |
|
|
H1.11 |
Light PVC insulated and sheathed extensible leads |
H03VVH8-F H03VVH2H8-F |
running |
HD 21.10 S2 |
2 |
|
|
H1.12 |
Ordinary PVC
insulated and sheathed extensible leads |
H05VVH8-F H05VVH2H8-F |
running |
3 |
||
|
H1.13 |
Divisible,
two-layer insulated cables for Class II luminaires |
H03VH7H-F |
running |
HD 21.11 S1 + /A1:2001 |
3 |
|
|
H1.14 |
Heat-resistant
light PVC sheathed cords for a maximum conductor temperature of |
H03V2V2-F H03V2V2H2-F |
running |
HD 21.12 S1 + /A1:2001 |
2 |
|
|
H1.15 |
Heat-resistant
Ordinary PVC sheathed cords for a maximum conductor temperature of 90°C |
H05V2V2-F H05V2V2H2-F |
running |
3 |
||
|
H1.16 |
Heat-resistant
Ordinary PVC sheathed cords with strain
bearing members for a maximum conductor temperature of |
H05V2V2D3-F |
running |
4 |
||
|
H1.17 |
Oil resistant
PVC sheathed, unscreened cables with two or more conductors |
H05VV5-F |
running |
HD 21.13 S1 + /A1:2001 |
3 |
|
|
H1.18 |
Oil resistant
PVC sheathed, screened cables with two or more conductors |
H05VVC4V5-K |
running |
4 |
||
|
H1.19 |
Light
flexible cords insulated and sheathed with halogen free thermoplastics
compounds |
H03Z1Z1-F H03Z1Z1H2-F |
running |
HD 21.14 S1 |
3 |
|
|
H1.20 |
Ordinary
flexible cords insulated and sheathed with halogen free thermoplastics
compounds |
H05Z1Z1-F H05Z1Z1H2-F |
running |
4 |
||
|
H1.21 |
Single core non-sheathed cable insulated with
halogen-free thermoplastic compound with rigid or flexible conductor for
general purposes (Type 1) |
H07Z1-U H07Z1-R H07Z1-K |
running |
HD 21.15 S1 |
4 and 5 |
|
|
H1.22 |
Single core non-sheathed cable insulated with
halogen-free thermoplastic compound with rigid or flexible conductor for
general purposes (Type 2) |
H07Z1-U H07Z1-R H07Z1-K |
running |
4 and 5 |
||
|
H1.23 |
Single core non-sheathed cable insulated with
halogen-free thermoplastic compound with rigid or flexible conductor for
internal wiring |
H05Z1-U H05Z1-R H05Z1-K |
running |
6 and 7 |
||
|
2. CROSS-LINKED
INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V |
||||||
|
H2.1 |
Heat
resistant silicon rubber insulated cables for a maximum conductor temperature
of 180 °C |
H05SJ-K H05SJ-U |
running |
HD 22.3 S4 + /A1:2006 |
2 |
|
|
H2.2 |
Unbraided
heat resistant silicon rubber insulated cables for a maximum conductor
temperature of 180 °C |
H05S-U H05S-K |
running |
3 |
||
|
H2.3 |
Heat
resistant silicone rubber sheathed single core cables |
H05SS-K |
running |
4 |
||
|
H2.4 |
Spare |
|||||
|
H2.5 |
Ordinary
tough rubber sheathed cords and flexible cables |
H05RR-F |
running |
HD 22.4 S4 |
3 |
|
|
H2.6 |
Ordinary PCP or other equivalent synthetic elastomer
sheathed cords and flexible cables |
H05RN-F |
running |
4 |
||
|
H2.7 |
Heavy PCP or other equivalent synthetic elastomer
sheathed flexible cables |
H07RN-F |
running |
5 |
||
|
H2.8 |
Heavy PCP or other equivalent synthetic elastomer
sheathed flexible cables with more than five conductors |
H07RN-F |
running |
6 |
||
|
H2.9 |
Arc welding
cables |
H01N2-D H01N2-E |
running |
HD 22.6 S2 + /A1:1999 +/A2:2004 |
2 |
|
|
H2.10 |
Cables with
increased heat resistance for internal wiring for a conductor temperature of |
H07G-U H07G-R H07G-K |
running |
HD 22.7 S2 + /A1:1999 + /A2:2004 |
2 |
|
|
H2.11 |
Cables with
increased heat resistance for internal wiring for a conductor temperature of
110 °C |
H05G-U H05G-K |
running |
3 |
||
|
H2.12 |
PCP or
equivalent synthetic elastomer sheathed cables for use as decorative chains |
H05RN-F H05RNH2-F |
running |
HD 22.8 S2 + /A1:1999 |
2 |
|
|
H2.13 |
PCP or
equivalent synthetic elastomer sheathed cables for decorative chains used with designated
lampholders |
H03RN-F |
running |
3 |
||
|
H2.14 |
Single core
non sheathed cables with rigid conductors for general purposes |
H07Z-U H07Z-R |
running |
HD 22.9 |
2 |
|
|
H2.15 |
Single core
non sheathed cables with flexible conductors for general purposes |
H07Z-K |
running |
3 |
||
|
H2.16 |
Single core
non sheathed cables with solid conductors for internal wiring |
H05Z-U |
running |
4 |
||
|
H2.17 |
Single core
non sheathed cables with flexible conductors for internal wiring |
H05Z-K |
running |
5 |
||
|
H2.18 |
EPR insulated
and polyurethane sheathed flexible cable |
H05BQ-F |
running |
HD 22.10 S2 |
3 |
|
|
H2.19 |
EPR insulated
and polyurethane sheathed flexible cable |
H07BQ-F |
running |
4 |
||
|
H2.20 |
EVA cords and
flexible cables |
H05GG-F H05GGH2-F |
running |
HD 22.11 S2 |
3 |
|
|
H2.21 |
Ordinary
heat-resistant EPR or equivalent synthetic elastomer insulated and sheathed
cord and cable for a maximum conductor temperature of |
H05BB-F |
running |
HD 22.12 S2 |
3 |
|
|
H2.22 |
Heavy
heat-resistant EPR or equivalent synthetic elastomer insulated and sheathed
cord and cable for a maximum conductor temperature of |
H07BB-F |
running |
4 |
||
|
H2.23 |
Ordinary
heat-resistant EPR or equivalent synthetic elastomer insulated and CSP or
equivalent synthetic elastomer sheathed cord and cable for a maximum
conductor temperature of |
H05BN4-F |
running |
5 |
||
|
H2.24 |
Heat-resistant
EPR or equivalent synthetic elastomer insulated heavy CSP or equivalent
synthetic elastomer sheathed cord and cable for a maximum conductor
temperature of 90°C |
H07BN4-F |
running |
6 |
||
|
H2.25 |
Heat-resistant
EPR or equivalent synthetic elastomer insulated heavy CSP or equivalent
synthetic elastomer sheathed cord and cable for a maximum conductor
temperature of 90 °C (multicore cables) |
H07BN4-F |
running |
7 |
||
|
H2.26 |
Single and
multicore flexible cables, insulated and sheathed with cross-linked polymer
and having low emission of smoke and corrosive gases. Cables with one to five
cores |
H07ZZ-F |
running |
HD 22.13 S2 |
3 |
|
|
H2.27 |
Multicore
flexible cables, insulated and sheathed with cross-linked polymer and having
low emission of smoke and corrosive gases. Cables with more than five cores |
H07ZZ-F |
running |
4 |
||
|
H2.28 |
EPR insulated
and sheathed cords for applications requiring high flexibility |
H03RR-H |
running |
HD 22.14 S3 |
3 |
|
|
H2.29 |
Spare |
--- |
||||
|
H2.30 |
Cross-linked
PVC (XLPVC) insulated and sheathed cords for applications requiring high
flexibility |
H03V4V4-H |
running |
5 |
||
|
H2.31 |
EPR insulated
and braided cords for applications requiring high flexibility |
H03RT-H |
running |
6 |
||
|
H2.32 |
Heat
resistance silicone rubber sheathed multicore flexible cables without
strain-bearing element |
H05SS-F H05SST-F |
running |
HD 22.15 S2 |
3 |
|
|
H2.33 |
Heat
resistance silicone rubber sheathed multicore cables with strain-bearing
element |
H05SSD3-K H05SSD3T-K |
running |
HD 22.15 S2 |
4 |
|
|
H2.34 |
Water
resistant polychloroprene or equivalent synthetic elastomer sheathed cables |
H07RN8-F |
running |
HD 22.16 S2 |
3 |
|
|
H2.35 |
Water
resistant polychloroprene or other equivalent synthetic elastomer
sheathed flexible cable with more than
five conductors (multicore cables) |
H07RN8-F |
running |
4 |
||
|
3. FLAT PVC
SHEATHED FLEXIBLE CABLES |
||||||
|
H3.1 |
Spare |
|||||
|
H3.2 |
Flat PVC
sheathed flexible cables for low rise lifts |
H05VVH6-F H05VVD3H6-F |
running |
EN 50214:2006 |
5 |
|
|
H3.3 |
Flat PVC
sheathed flexible cables for high rise, high speed lifts |
H05V3V3H6-F H05V3V3D3H6-F |
running |
6 |
||
|
H3.4 |
Flat PVC
sheathed flexible cables for lifts and similar applications |
H07VVH6-F H07VVD3H6-F |
running |
7 |
||
|
4. SPARE |
||||||
|
5. MINERAL
INSULATED CABLES WITH A RATED VOLTAGE NOT EXCEEDING 750 V |
||||||
|
H5.1 |
Spare |
|||||
|
H5.2 |
Spare |
|||||
|
H5.3 |
500 V mineral
insulated cables (light duty
grade) |
500 V |
running |
EN
60702-1:2002 |
4.1 |
|
|
H5.4 |
750 V mineral
insulated cables (heavy duty
grade) |
750 V |
running |
4.2 |
||
|
6. CABLES
FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM |
||||||
|
H6.1 |
Rubber
insulated lead sheathed cables |
Type
A |
running |
2012-01-31 (cancellation) |
EN
50143:2009 |
6 |
|
H6.2 |
Silicone
rubber insulated cables: |
7 |
||||
|
Unscreened,
unsheathed |
Type
B |
2009-02-01 |
2012-01-31 |
|
||
|
Unscreened,
PVC sheathed |
Type
C1 |
running |
2012-01-31 (cancellation) |
|
||
|
Unscreened,
halogen free sheathed |
Type
C2 |
2009-02-01 |
2012-01-31 |
|||
|
Screened and PVC sheathed |
Type
D1 |
running |
2012-01-31 (cancellation) |
|||
|
Screened and halogen free sheathed |
Type
D2 |
2009-02-01 |
2012-01-31 |
|||
|
H6.3 |
PVC
insulated cables |
EN
50143:2009 |
8 |
|||
|
|
Screened
and PVC sheathed |
Type E |
2009-02-01 |
2012-01-31 |
|
|
|
Unscreened
PVC sheathed |
Type F |
2009-02-01 |
2012-01-31 |
|||
|
Unscreened,
unsheathed |
Type G |
2009-02-01 |
2012-01-31 |
|||
|
H6.4 |
Cable
with a composite insulation of polyethylene and PVC |
Type H |
running |
2012-01-31 (cancellation) |
9 |
|
|
Cable
with a reduced thickness composite insulation of polyethylene and PVC |
Type
K |
2009-02-01 |
2012-01-31 |
|
||
|
H6.5 |
Silicone Rubber insulated cables (3/6 kV) |
Type
L |
2009-02-01 |
2012-01-31 |
10 |
|
|
7. CABLES
FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT |
||||||
|
H7.1 |
Earthing and
short-circuiting cables: - EPR/Copper -
EPR/Aluminium - PVC/Copper
(T from - PVC/Aluminium
(T from - PVC/Copper
(T from -
PVC/Aluminium (T from |
61138 IEC 110 61138 IEC 210 H00V-D H00V-AD H00V3-D H00V3-AD |
2007-10-01 |
2009-10-01 (dow) |
EN 61138:2007 |
--- |
|
H7.2 |
-
SiR – Copper -
SiR – Aluminium |
H00S-D H00S-AD |
2007-10-01 |
2009-10-01 |
EN 61138:2007 |
--- |