| GrCod |
Description |
Code Designation |
Standard or Harmonisation Document |
DOR (yy-mm-dd) |
DOW (yy-mm-dd) |
HAR PD 7 TABLE 1 Ed. 2006-05 THERMOPLASTIC INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V |
| H1.1 |
Flat tinsel cords |
H03 VH-Y |
HD 21.5 S3 clause 2 A1:1999 A2:2001 |
93-12-08 99-08-01 01-03-01 |
03-04-01 94-12-01 01-08-01 |
| H1.3 |
Light PVC sheathed cords (round) Light PVC sheathed cords (flat) |
H03 VV-F H03 VVH2-F |
HD 21.5 S3 clause 4 A1:1999 A2:2001 |
93-12-08 99-08-01 01-03-01 |
03-04-01 94-12-01 01-08-01 |
| H1.4 |
Ordinary PVC sheathed cords (round) Ordinary PVC sheathed cords (flat) |
H05 VV-F H05 VVH2-F |
HD 21.5 S3 clause 5 A1:1999 A2:2001 |
93-12-08 99-08-01 01-03-01 |
03-04-01 94-12-01 01-08-01 |
| H1.5 |
Single core non- sheathed cables with solid or flexible conductor for internal wiring |
H05 V-U H05 V-K |
HD 21.3 S3 clause 4 and 5 A1:1999 |
94-12-06 99-08-01 |
95-12-01 01-08-01 |
| H1.6 |
Single core non-sheathed cables with solid or flexible conductor for general purposes |
H07 V-U H07 V-R H07 V-K |
HD 21.3 S3 clause 2 and 3 A1:1999 |
94-12-06 99-08-01 |
95-12-01 01-08-01 |
| H1.7 |
Single core non-sheathed cables for internal wiring for a conductor temperature of 90 °C |
H05 V2-U H05 V2-K H05 V2-R |
HD 21.7 S2 clause 2 A1:1999 |
95-11-28 99-08-01 |
96-09-01 01-08-01 |
| H1.8 |
Single core non-sheathed cables for internal wiring for a conductor temperature of 90 °C |
H07 V2-U H07 V2-K H07 V2-R |
HD 21.7 S2 clause 3 A1:1999 |
95-11-28 99-08-01 |
96-09-01 01-08-01 |
| H1.9 |
Single core insulated cables for indoor decorative lighting chains |
H03 VH7-H |
HD 21.8 S2 |
99-08-01 |
01-08-01 |
| H1.10 |
Single core non-sheathed cables with rigid or flexible conductor for installation at low temperature |
H07 V3-U H07 V3-R H07 V3-K |
HD 21.9 S2 clause 2 and 3 A1:1999 |
94-12-06 99-08-01 |
95-12-01 01-08-01 |
| H1.11 |
Light PVC insulated and sheathed extensible leads |
H03 VVH8-F H03 VVH2H8-F |
HD 21.10 S2 Clause 2 |
01-07-01 |
03-08-01 |
| H1.12 |
Ordinary PVC insulated and sheathed extensible leads |
H05 VVH8-F H05 VVH2H8-F |
HD 21.10 S2 Clause 3 |
01-07-01 |
03-08-01 |
| H1.13 |
Divisible, two-layer insulated cables for Class II luminaires |
H03 VH7H-F |
HD 21.11 S1 clause 2 A1:2001 |
95-03-06 01-06-01 |
96-03-01 03-08-01 |
| H1.14 |
Heat-resistant light PVC sheathed cord for a maximum conductor temperature of 90 °C |
H03 V2V2-F H03 V2V2H2-F |
HD 21.12 S1 clause 2 + A1:2001 |
94-07-05 01-06-01 |
95-07-15 03-08-01 |
| H1.15 |
Heat-resistant ordinary PVC sheathed cord for a maximum conductor temperature of 90 °C |
H05 V2V2-F H05V2V2H2-F |
HD 21.12 S1 clause 3 A1:2001 |
94-07-05 01-06-01 |
95-07-15 03-08-01 |
| H1.16 |
Heat-resistant ordinary PVC sheathed cord with strain bearing members for a maximum conductor temperature of 90 °C |
H05 V2V2D3-F |
HD 21.12 S1 clause 4 A1:2001 |
94-07-05 01-06-01 |
95-07-15 03-08-01 |
| H1.17 |
Oil resistant PVC sheathed, unscreened cables with two or more conductors |
H05 VV5-F |
HD 21.13 S1 clause 3 A1:2001 |
95-07-04 01-06-01 |
96-07-01 03-08-01 |
| H1.18 |
Oil resistant PVC sheathed, screened cables with two or more conductors |
H05 VVC4V5-K |
HD 21.13 S1 clause 4 A1:2001 |
95-07-04 01-06-01 |
96-07-01 03-08-01 |
| H1.19 |
Light flexible cords insulated and sheathed with halogen-free thermoplastic compounds |
H03Z1Z1-F H03Z1Z1H2-F |
HD 21.14 S1 clause 3 |
03-05-01 |
06-05-01 |
| H1.20 |
Ordinary flexible cords insulated and sheathed with halogen-free thermoplastic compounds |
H05Z1Z1-F H05Z1Z1H2-F |
HD 21.14 S1 clause 4 |
03-05-01 |
06-05-01 |
HARD PD7 TABLE 2 CROSS-LINKED INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V |
| H2.1 |
Heat resistant silicon rubber insulated cables for a maximum conductor temperature of 180 °C |
H05 SJ-K H05SJ-U |
HD 22.3 S4 clause 2 + A1:2006 |
04-02-01 05-12-01 |
06-02-01 07-12-01 |
| H2.2 |
Unbraided heat resistant silicon rubber insulated cables for a maximum conductor temperature of 180 °C |
H05 S-U H05 S-K |
HD 22.3 S4 clause 3 |
04-02-01 |
06-02-01 |
| H2.3 |
Heat resistant silicone rubber sheathed single core cables |
H05 SS-K |
HD 22.3 S4 clause 4 |
04-02-01 |
06-02-01 |
| H2.5 |
Ordinary tough rubber sheathed cord and flexible cables |
H05 RR-F |
HD 22.4 S4 clause 3 |
04-02-01 |
06-02-01 |
| H2.6 |
Ordinary PCP or other equivalent synthetic elastomer sheathed cords and flexible cables |
H05 RN-F |
HD 22.4 S4 clause 4 |
04-02-01 |
06-02-01 |
| H2.7 |
Heavy PCP or other equivalent synthetic elastomer sheathed flexible cables |
H07 RN-F |
HD 22.4 S4 clause 5 |
04-02-01 |
06-02-01 |
| H2.8 |
Heavy PCP or other equivalent synthetic elastomer sheathed flexible cables with more than five conductors |
H07 RN-F |
HD 22.4 S4 clause 6 |
04-02-01 |
06-02-01 |
| H2.9 |
Arc welding cables |
H01 N2-D H01 N2-E |
HD 22.6 S2 A1:1999 A2:2004 |
95-05-15 98-08-01 04-02-01 |
96-07-01 00-06-01 06-02-01 |
| H2.10 |
Cables with increased heat resistance for internal wiring for a conductor temperature of 110 °C |
H07 G-U H07 G-R H07 G-K |
HD 22.7 S2 clause 2 A1:1999 A2:2004 |
95-05-15 98-08-01 04-02-01 |
96-07-01 00-06-01 06-02-01 |
| H2.11 |
Cables with increased heat resistance for internal wiring for a conductor temperature of 110 °C |
H05 G-U H05 G-K |
HD 22.7 S2 clause 3 A1:1999 A2:2004 |
95-05-15 98-08-01 04-02-01 |
96-07-01 00-06-01 06-02-01 |
| H2.12 |
PCP or equivalent synthetic elastomer sheathed cables for use as decorative chains |
H05 RN-F H05 RNH2-F |
HD 22.8 S2 clause 2 A1:1999 |
94-05-15 98-08-01 |
95-07-15 00-06-01 |
| H2.13 |
PCP or equivalent synthetic elastomer sheathed cables for decorative chains used with designated lampholders |
H03 RN-F |
HD 22.8 S2 clause 3 A1:1999 |
94-05-15 98-08-01 |
95-07-15 00-06-01 |
| H2.14 |
Single core non-sheathed cable with rigid conductors for general purposes |
H07 Z-U H07 Z-R |
HD 22.9 S2 clause 2 A1:1999 |
95-05-15 98-08-01 |
96-07-01 00-06-01 |
| H2.15 |
Single core non-sheathed cable with flexible conductors for general purposes |
H07 Z-K |
HD 22.9 S2 clause 3 A1:1999 |
95-05-15 98-08-01 |
96-07-01 00-06-01 |
| H2.16 |
Single core non-sheathed cable with solid conductors for internal wiring |
H05 Z-U |
HD 22.9 S2 clause 4 A1:1999 |
95-05-15 98-08-01 |
96-07-01 00-06-01 |
| H2.17 |
Single core non-sheathed cable with flexible conductors for internal wiring |
H05 Z-K |
HD 22.9 S2 clause 5 A1:1999 |
95-05-15 98-08-01 |
96-07-01 00-06-01 |
| H2.18 |
EPR insulated and polyurethane sheathed flexible cable |
H05 BQ-F |
HD 22.10 S1 clause 2 A1:1999 |
94-05-15 98-08-01 |
95-07-15 00-06-01 |
| H2.19 |
EPR insulated and polyurethane sheathed flexible cable |
H07 BQ-F |
HD 22.10 S1 clause 3 A1:1999 |
94-05-15 98-08-01 |
95-07-15 00-06-01 |
| H2.20 |
EVA cords and flexible cables |
H05 GG-F H05GGH2-F |
HD 22.11 S1 clause 2 A1:1999 |
95-02-15 98-08-01 |
96-03-01 00-06-01 |
| H2.21 |
Ordinary heat-resistant EPR or equivalent synthetic elastomer insulated and sheathed cord and cable for a maximum conductor temperature of 90 °C |
H05 BB-F |
HD 22.12 S1 clause 3 A1:1999 |
96-03-05 98-08-01 |
97-03-01 00-06-01 |
| H2.22 |
Heavy heat-resistant EPR or equivalent synthetic elastomer insulated and sheathed cord and cable for a maximum conductor temperature of 90 °C |
H07 BB-F |
HD 22.12 S1 clause 4 A1:1999 |
96-03-05 98-08-01 |
97-03-01 00-06-01 |
| H2.23 |
Ordinary heat-resistant EPR or equivalent synthetic elastomer insulated and sheathed cord and cable for a maximum conductor temperature of 90 °C |
H05 BN4-F |
HD 22.12 S1 clause 5 A1:1999 |
96-03-05 98-08-01 |
97-03-01 00-06-01 |
| H2.24 |
Heat-resistant EPR or equivalent synthetic elastomer insulated heavy CSP or equivalent synthetic elastomer sheathed cord and cable for a maximum conductor temperature of 90 °C |
H07 BN4-F |
HD 22.12 S1 clause 6 A1:1999 |
96-03-05 98-08-01 |
97-03-01 00-06-01 |
| H2.25 |
Heat-resistant EPR or equivalent synthetic elastomer insulated heavy CSP or equivalent synthetic elastomer sheathed cord and cable for a maximum conductor temperature of 90 °C (multicore cables) |
H07 BN4-F |
HD 22.12 S1 clause 7 A1:1999 |
96-03-05 98-08-01 |
97-03-01 00-06-01 |
| H2.26 |
Single and multicore flexible cables, insulated and sheathed with cross-linked polymer and having low emission of smoke and corrosive gases. Cables with one to five cores |
H07 ZZ-F |
HD 22.13 S1 clause 3 A1:2000 |
96-03-05 99-08-01 |
97-03-01 01-08-01 |
| H2.27 |
Multicore flexible cables, insulated and sheathed with cross-linked polymer and having low emission of smoke and corrosive gases. Cables with more than five cores |
H07 ZZ-F |
HD 22.13 S1 clause 4 A1:2000 |
96-03-05 99-08-01 |
97-03-01 01-08-01 |
| H2.28 |
EPR insulated and sheathed cords for applications requiring high flexibility |
H03 RR-H |
HD 22.14 S2 clause 3 |
02-09-01 |
03-09-01 |
| H2.29 |
Cords for applications requiring high flexibility |
H03 RV4-H |
HD 22.14 S2 |
02-09-01 |
03-09-01 |
| H2.30 |
Cross-linked PVC (XLPVC) insulated and sheathed cords for applications requiring high flexibility |
H03 V4V4-H |
HD 22.14 S2 clause 5 |
02-09-01 |
03-09-01 |
| H2.31 |
EPR insulated and braided cords for applications requiring high flexibility |
H03 RT-H |
HD 22.14 S2 clause 6 |
02-09-01 |
03-09-01 |
| H2.32 |
Heat resistance silicone rubber sheathed multicore cables without strain-bearing element |
H05 SS-F H05 SST-F |
HD 22.15 S1 clause 3 |
99-04-01 |
01-04-01 |
| H2.33 |
Heat resistance silicone rubber sheathed multicore cables with strain-bearing element |
H05 SSD3-K H05 SSD3T-K |
HD 22.15 S1 clause 4 |
99-04-01 |
01-04-01 |
| H2.34 |
Water resistant polychloroprene or equivalent synthetic elastomer sheathed cables |
H07 RN8-F |
HD 22.16 S1 clause 3 |
99-08-01 |
01-08-01 |
| H2.35 |
Water resistant polychloroprene or other equivalent synthetic elastomer sheathed flexible cable with more than five conductors (multicore cables) |
H07 RN8-F |
HD 22.16 S1 clause 4 |
99-08-01 |
01-08-01 |
HARD PD 7 TABLE 3 FLAT PVC SHEATHED FLEXIBLE CABLES |
| H3.2 |
Flat PVC sheathed flexible cables for lifts and similar applications |
H07 VVH6-F H07 VVD3H6-F |
HD 359 S2 |
89-09-11 |
90-12-01 |
| H3.3 |
Flat PVC sheathed flexible cables for low rise lifts |
H05 VVH6-F H05 VVD3H6-F |
EN 50214 clause 5.1 |
96-12-09 |
97-12-01 |
| H3.4 |
Flat PVC sheathed flexible cables for high rise, high speed lifts |
H05 V3V3H6-F H05 V3V3D3H6-F |
EN 50214 clause 5.2 |
96-12-09 |
97-12-01 |
HAR PD 7 TABLE 5 MINERAL INSULATED CABLE WITH A RATED VOLTAGE NOT EXCEEDING 750 V |
| H5.1 |
500 V mineral insulated cables (light duty grade) |
L |
HD 586.1 S1 |
93-09-22 |
05-03-01 |
| H5.2 |
750 V mineral insulated cables (heavy duty grade) |
H |
HD 586.1 S1 |
93-09-22 |
05-03-01 |
| H5.3 |
500 V mineral insulated cables (light duty grade) |
500 V |
EN 60702-1 |
02-03-01 |
05-03-01 |
| H5.4 |
750 V mineral insulated cables (heavy duty grade) |
750 V |
EN 60702-1 |
02-03-01 |
05-03-01 |
HAR PD 7 TABLE 6 CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1 kV BUT NOT EXCEEDING 10 kV |
| H6.1 |
Rubber insulated lead sheathed cables |
Type A |
EN 50143 clause 6 A1:2003 |
96-12-09 03-02-01 |
97-12-01 05-02-01 |
| H6.2 |
Silicone rubber insulated cables: - unscreened, unsheathed - unscreened, PVC sheathed - unscreened, halogen-free sheathed - screened and PVC sheathed - screened and halogen-free sheathed |
Type B Type C1 Type C2 Type D1 Type D2 |
EN 50143 clause 7 A1:2003 |
96-12-09 03-02-01 |
97-12-01 05-02-01 |
| H6.3 |
PVC insulated cables: - screened and PVC sheathed - unscreened PVC sheathed - unscreened, unsheathed |
Type E Type F Type G |
EN 50143 clause 8 A1:2003 |
96-12-09 03-02-01 |
97-12-01 05-02-01 |
| H6.4 |
- Cable with a composite insulation of polyethylene and PVC
- Cable with a reduced thickness composite insulation of polyethylene and PVC |
Type H Type K |
EN 50143 clause 9 |
96-12-09 03-02-01 |
97-12-01 05-02-01 |
HAR PD 7 TABLE 7 CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT |
| H7.1 |
Earthing and short-circuiting cables:
- EPR/Copper - EPR/Aluminium - PVC/Copper - PVC/Aluminium - PVC/Copper - PVC/Aluminium |
61138 IEC 110 61138 IEC 210 H00V-D H00V-AD H00V3-D H00V3-AD |
EN 61138 A11:2003 |
97-03-11 03-02-01 |
97-12-01 05-02-01 |
HAR PD 7 TABLE 8 RESIDUAL RECOGNISED NATIONAL TYPES |
| H8.1 |
500, 630, 800 and 1000 mm² |
H07V-R |
CLC/TR 50424:2004 clause 2.1 |
04-06-03 |
-- |
| H8.2 |
5 core, 35-300 mm² |
H07BB-F |
CLC/TR 50424:2004 clause 2.8 |
04-06-03 |
-- |
| H8.3 |
Single core, 630 mm² |
H07BN4-F |
CLC/TR 50424:2004 clause 2.9 |
04-06-03 |
-- |
| H8.4 |
Single core, 630 mm² |
H07ZZ-F |
CLC/TR 50424:2004 clause 2.10 |
04-06-03 |
-- |
| H8.5 |
Single core, 630 mm² |
H07RN8-F |
CLC/TR 50424:2004 clause 2.11 |
04-06-03 |
-- |
| H8.6 |
4 and 5 core, 25 mm² |
H07VVH6-F H07VVD3H6-F |
CLC/TR 50424:2004 clause 2.12 |
04-06-03 |
-- |