Search 

PRODUCTS ENTERING INTO THE SCOPE OF THE HAR AGREEMENT
 
 
GrCod Description Code Designation Standard or Harmonisation Document DOR (yy-mm-dd) DOW (yy-mm-dd)
HAR PD 7 TABLE 1 Ed. 2006-05
THERMOPLASTIC INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V
H1.1 Flat tinsel cords H03 VH-Y HD 21.5 S3
clause 2
A1:1999
A2:2001
93-12-08
 
99-08-01
01-03-01
03-04-01
 
94-12-01
01-08-01
H1.3 Light PVC sheathed cords (round)
Light PVC sheathed cords (flat)
H03 VV-F
H03 VVH2-F
HD 21.5 S3
clause 4
A1:1999
A2:2001
93-12-08
 
99-08-01
01-03-01
03-04-01
 
94-12-01
01-08-01
H1.4 Ordinary PVC sheathed cords (round)
Ordinary PVC sheathed cords (flat)
H05 VV-F
H05 VVH2-F
HD 21.5 S3
clause 5
A1:1999
A2:2001
93-12-08
 
99-08-01
01-03-01
03-04-01
 
94-12-01
01-08-01
H1.5 Single core non- sheathed cables with solid or flexible conductor for internal wiring H05 V-U
H05 V-K
HD 21.3 S3
clause 4 and 5
A1:1999
94-12-06
 
99-08-01
95-12-01
 
01-08-01
H1.6 Single core non-sheathed cables with solid or flexible conductor for general purposes H07 V-U
H07 V-R
H07 V-K
HD 21.3 S3
clause 2 and 3
A1:1999
94-12-06
 
99-08-01
95-12-01
 
01-08-01
H1.7 Single core non-sheathed cables for internal wiring for a conductor temperature of 90 °C H05 V2-U
H05 V2-K
H05 V2-R
HD 21.7 S2
clause 2
A1:1999
95-11-28
 
99-08-01
96-09-01
 
01-08-01
H1.8 Single core non-sheathed cables for internal wiring for a conductor temperature of 90 °C H07 V2-U
H07 V2-K
H07 V2-R
HD 21.7 S2
clause 3
A1:1999
95-11-28
 
99-08-01
96-09-01
 
01-08-01
H1.9 Single core insulated cables for indoor decorative lighting chains H03 VH7-H HD 21.8 S2 99-08-01 01-08-01
H1.10 Single core non-sheathed cables with rigid or flexible conductor for installation at low temperature H07 V3-U
H07 V3-R
H07 V3-K
HD 21.9 S2
clause 2 and 3
A1:1999
94-12-06
 
99-08-01
95-12-01
 
01-08-01
H1.11 Light PVC insulated and sheathed extensible leads H03 VVH8-F
H03 VVH2H8-F
HD 21.10 S2
Clause 2
01-07-01 03-08-01
H1.12 Ordinary PVC insulated and sheathed extensible leads H05 VVH8-F
H05 VVH2H8-F
HD 21.10 S2
Clause 3
01-07-01 03-08-01
H1.13 Divisible, two-layer insulated cables for Class II luminaires H03 VH7H-F HD 21.11 S1
clause 2
A1:2001
95-03-06
 
01-06-01
96-03-01
 
03-08-01
H1.14 Heat-resistant light PVC sheathed cord for a maximum conductor temperature of 90 °C H03 V2V2-F
H03 V2V2H2-F
HD 21.12 S1
clause 2
+ A1:2001
94-07-05
 
01-06-01
95-07-15
 
03-08-01
H1.15 Heat-resistant ordinary PVC sheathed cord for a maximum conductor temperature of 90 °C H05 V2V2-F
H05V2V2H2-F
HD 21.12 S1
clause 3
A1:2001
94-07-05
 
01-06-01
95-07-15
 
03-08-01
H1.16 Heat-resistant ordinary PVC sheathed cord with strain bearing members for a maximum conductor temperature of 90 °C H05 V2V2D3-F HD 21.12 S1
clause 4
A1:2001
94-07-05
 
01-06-01
95-07-15
 
03-08-01
H1.17 Oil resistant PVC sheathed, unscreened cables with two or more conductors H05 VV5-F HD 21.13 S1
clause 3
A1:2001
95-07-04
 
01-06-01
96-07-01
 
03-08-01
H1.18 Oil resistant PVC sheathed, screened cables with two or more conductors H05 VVC4V5-K HD 21.13 S1
clause 4
A1:2001
95-07-04
 
01-06-01
96-07-01
 
03-08-01
H1.19 Light flexible cords insulated and sheathed with halogen-free thermoplastic compounds H03Z1Z1-F
H03Z1Z1H2-F
HD 21.14 S1
clause 3
03-05-01 06-05-01
H1.20 Ordinary flexible cords insulated and sheathed with halogen-free thermoplastic compounds H05Z1Z1-F
H05Z1Z1H2-F
HD 21.14 S1
clause 4
03-05-01 06-05-01
HARD PD7 TABLE 2
CROSS-LINKED INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V
H2.1 Heat resistant silicon rubber insulated cables for a maximum conductor temperature of 180 °C H05 SJ-K
H05SJ-U
HD 22.3 S4
clause 2
+ A1:2006
04-02-01
05-12-01
06-02-01
07-12-01
H2.2 Unbraided heat resistant silicon rubber insulated cables for a maximum conductor temperature of 180 °C H05 S-U
H05 S-K
HD 22.3 S4
clause 3
04-02-01 06-02-01
H2.3 Heat resistant silicone rubber sheathed single core cables H05 SS-K HD 22.3 S4
clause 4
04-02-01 06-02-01
H2.5 Ordinary tough rubber sheathed cord and flexible cables H05 RR-F HD 22.4 S4
clause 3
04-02-01 06-02-01
H2.6 Ordinary PCP or other equivalent synthetic elastomer sheathed cords and flexible cables H05 RN-F HD 22.4 S4
clause 4
04-02-01 06-02-01
H2.7 Heavy PCP or other equivalent synthetic elastomer sheathed flexible cables H07 RN-F HD 22.4 S4
clause 5
04-02-01 06-02-01
H2.8 Heavy PCP or other equivalent synthetic elastomer sheathed flexible cables with more than five conductors H07 RN-F HD 22.4 S4
clause 6
04-02-01 06-02-01
H2.9 Arc welding cables H01 N2-D
H01 N2-E
HD 22.6 S2
A1:1999
A2:2004
95-05-15
98-08-01
04-02-01
96-07-01
00-06-01
06-02-01
H2.10 Cables with increased heat resistance for internal wiring for a conductor temperature of 110 °C H07 G-U
H07 G-R
H07 G-K
HD 22.7 S2
clause 2
A1:1999
A2:2004
95-05-15
 
98-08-01
04-02-01
96-07-01
 
00-06-01
06-02-01
H2.11 Cables with increased heat resistance for internal wiring for a conductor temperature of 110 °C H05 G-U
H05 G-K
HD 22.7 S2
clause 3
A1:1999
A2:2004
95-05-15
 
98-08-01
04-02-01
96-07-01
 
00-06-01
06-02-01
H2.12 PCP or equivalent synthetic elastomer sheathed cables for use as decorative chains H05 RN-F
H05 RNH2-F
HD 22.8 S2
clause 2
A1:1999
94-05-15
 
98-08-01
95-07-15
 
00-06-01
H2.13 PCP or equivalent synthetic elastomer sheathed cables for decorative chains used with designated lampholders H03 RN-F HD 22.8 S2
clause 3
A1:1999
94-05-15
 
98-08-01
95-07-15
 
00-06-01
H2.14 Single core non-sheathed cable with rigid conductors for general purposes H07 Z-U
H07 Z-R
HD 22.9 S2
clause 2
A1:1999
95-05-15
 
98-08-01
96-07-01
 
00-06-01
H2.15 Single core non-sheathed cable with flexible conductors for general purposes H07 Z-K HD 22.9 S2
clause 3
A1:1999
95-05-15
 
98-08-01
96-07-01
 
00-06-01
H2.16 Single core non-sheathed cable with solid conductors for internal wiring H05 Z-U HD 22.9 S2
clause 4
A1:1999
95-05-15
 
98-08-01
96-07-01
 
00-06-01
H2.17 Single core non-sheathed cable with flexible conductors for internal wiring H05 Z-K HD 22.9 S2
clause 5
A1:1999
95-05-15
 
98-08-01
96-07-01
 
00-06-01
H2.18 EPR insulated and polyurethane sheathed flexible cable H05 BQ-F HD 22.10 S1
clause 2
A1:1999
94-05-15
 
98-08-01
95-07-15
 
00-06-01
H2.19 EPR insulated and polyurethane sheathed flexible cable H07 BQ-F HD 22.10 S1
clause 3
A1:1999
94-05-15
 
98-08-01
95-07-15
 
00-06-01
H2.20 EVA cords and flexible cables H05 GG-F
H05GGH2-F
HD 22.11 S1
clause 2
A1:1999
95-02-15
 
98-08-01
96-03-01
 
00-06-01
H2.21 Ordinary heat-resistant EPR or equivalent synthetic elastomer insulated and sheathed cord and cable for a maximum conductor temperature of 90 °C H05 BB-F HD 22.12 S1
clause 3
A1:1999
96-03-05
 
98-08-01
97-03-01
 
00-06-01
H2.22 Heavy heat-resistant EPR or equivalent synthetic elastomer insulated and sheathed cord and cable for a maximum conductor temperature of 90 °C H07 BB-F HD 22.12 S1
clause 4
A1:1999
96-03-05
 
98-08-01
97-03-01
 
00-06-01
H2.23 Ordinary heat-resistant EPR or equivalent synthetic elastomer insulated and sheathed cord and cable for a maximum conductor temperature of 90 °C H05 BN4-F HD 22.12 S1
clause 5
A1:1999
96-03-05
 
98-08-01
97-03-01
 
00-06-01
H2.24 Heat-resistant EPR or equivalent synthetic elastomer insulated heavy CSP or equivalent synthetic elastomer sheathed cord and cable for a maximum conductor temperature of 90 °C H07 BN4-F HD 22.12 S1
clause 6
A1:1999
96-03-05
 
98-08-01
97-03-01
 
00-06-01
H2.25 Heat-resistant EPR or equivalent synthetic elastomer insulated heavy CSP or equivalent synthetic elastomer sheathed cord and cable for a maximum conductor temperature of 90 °C (multicore cables) H07 BN4-F HD 22.12 S1
clause 7
A1:1999
96-03-05
 
98-08-01
97-03-01
 
00-06-01
H2.26 Single and multicore flexible cables, insulated and sheathed with cross-linked polymer and having low emission of smoke and corrosive gases. Cables with one to five cores H07 ZZ-F HD 22.13 S1
clause 3
A1:2000
96-03-05
 
99-08-01
97-03-01
 
01-08-01
H2.27 Multicore flexible cables, insulated and sheathed with cross-linked polymer and having low emission of smoke and corrosive gases. Cables with more than five cores H07 ZZ-F HD 22.13 S1
clause 4
A1:2000
96-03-05
 
99-08-01
97-03-01
 
01-08-01
H2.28 EPR insulated and sheathed cords for applications requiring high flexibility H03 RR-H HD 22.14 S2
clause 3
02-09-01 03-09-01
H2.29 Cords for applications requiring high flexibility H03 RV4-H HD 22.14 S2 02-09-01 03-09-01
H2.30 Cross-linked PVC (XLPVC) insulated and sheathed cords for applications requiring high flexibility H03 V4V4-H HD 22.14 S2
clause 5
02-09-01 03-09-01
H2.31 EPR insulated and braided cords for applications requiring high flexibility H03 RT-H HD 22.14 S2
clause 6
02-09-01 03-09-01
H2.32 Heat resistance silicone rubber sheathed multicore cables without strain-bearing element H05 SS-F
H05 SST-F
HD 22.15 S1
clause 3
99-04-01 01-04-01
H2.33 Heat resistance silicone rubber sheathed multicore cables with strain-bearing element H05 SSD3-K
H05 SSD3T-K
HD 22.15 S1
clause 4
99-04-01 01-04-01
H2.34 Water resistant polychloroprene or equivalent synthetic elastomer sheathed cables H07 RN8-F HD 22.16 S1
clause 3
99-08-01 01-08-01
H2.35 Water resistant polychloroprene or other equivalent synthetic elastomer sheathed flexible cable with more than five conductors (multicore cables) H07 RN8-F HD 22.16 S1
clause 4
99-08-01 01-08-01
HARD PD 7 TABLE 3
FLAT PVC SHEATHED FLEXIBLE CABLES
H3.2 Flat PVC sheathed flexible cables for lifts and similar applications H07 VVH6-F
H07 VVD3H6-F
HD 359 S2 89-09-11 90-12-01
H3.3 Flat PVC sheathed flexible cables for low rise lifts H05 VVH6-F
H05 VVD3H6-F
EN 50214
clause 5.1
96-12-09 97-12-01
H3.4 Flat PVC sheathed flexible cables for high rise, high speed lifts H05 V3V3H6-F
H05
V3V3D3H6-F
EN 50214
clause 5.2
96-12-09 97-12-01
HAR PD 7 TABLE 5
MINERAL INSULATED CABLE WITH A RATED VOLTAGE NOT EXCEEDING 750 V
H5.1 500 V mineral insulated cables
(light duty grade)
L HD 586.1 S1 93-09-22 05-03-01
H5.2 750 V mineral insulated cables
(heavy duty grade)
H HD 586.1 S1 93-09-22 05-03-01
H5.3 500 V mineral insulated cables
(light duty grade)
500 V EN 60702-1 02-03-01 05-03-01
H5.4 750 V mineral insulated cables
(heavy duty grade)
750 V EN 60702-1 02-03-01 05-03-01
HAR PD 7 TABLE 6
CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1 kV BUT NOT EXCEEDING 10 kV
H6.1 Rubber insulated lead sheathed cables Type A EN 50143
clause 6
A1:2003
96-12-09
 
03-02-01
97-12-01
 
05-02-01
H6.2 Silicone rubber insulated cables:
- unscreened, unsheathed
- unscreened, PVC sheathed
- unscreened, halogen-free sheathed
- screened and PVC sheathed
- screened and halogen-free sheathed
 
Type B
Type C1
Type C2
Type D1
Type D2
EN 50143
clause 7
A1:2003
96-12-09
 
03-02-01
97-12-01
 
05-02-01
H6.3 PVC insulated cables:
- screened and PVC sheathed
- unscreened PVC sheathed
- unscreened, unsheathed
 
Type E
Type F
Type G
EN 50143
clause 8
A1:2003
96-12-09
 
03-02-01
97-12-01
 
05-02-01
H6.4 - Cable with a composite insulation of polyethylene and PVC
- Cable with a reduced thickness composite insulation of polyethylene and PVC
Type H
 
 
Type K
EN 50143
clause 9
96-12-09
 
 
03-02-01
97-12-01
 
 
05-02-01
HAR PD 7 TABLE 7
CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
H7.1 Earthing and short-circuiting cables:

- EPR/Copper
- EPR/Aluminium
- PVC/Copper
- PVC/Aluminium
- PVC/Copper
- PVC/Aluminium
 
 
61138 IEC 110
61138 IEC 210
H00V-D
H00V-AD
H00V3-D
H00V3-AD
EN 61138
A11:2003
97-03-11
03-02-01
97-12-01
05-02-01
HAR PD 7 TABLE 8
RESIDUAL RECOGNISED NATIONAL TYPES
H8.1 500, 630, 800 and 1000 mm² H07V-R CLC/TR 50424:2004
clause 2.1
04-06-03 --
H8.2 5 core, 35-300 mm² H07BB-F CLC/TR 50424:2004
clause 2.8
04-06-03 --
H8.3 Single core, 630 mm² H07BN4-F CLC/TR 50424:2004
clause 2.9
04-06-03 --
H8.4 Single core, 630 mm² H07ZZ-F CLC/TR 50424:2004
clause 2.10
04-06-03 --
H8.5 Single core, 630 mm² H07RN8-F CLC/TR 50424:2004
clause 2.11
04-06-03 --
H8.6 4 and 5 core, 25 mm² H07VVH6-F
H07VVD3H6-F
CLC/TR 50424:2004
clause 2.12
04-06-03 --
 
© EEPCA 2003 - All rights reserved